Code: C-3102
Description: Fusing pressure release motor (M33) operation time abnormality 1. When M33 moves from the release position to the pressure position, the fusing pressure home sensor (PS58) does not turn ON within a specified period of time.
Causes: Fusing pressure home sensor (PS58) Fusing pressure release motor (M33) Printer control board (PRCB)
Remedy: 1 Check the fusing pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 13-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 5 Replace PS58. - 6 Replace M33. - 7 Replace PRCB.