Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-3802 — Konica-Minolta bizhub Pro 1051

Code: C-3802

Description: Thermistor /3 (TH3) low temperature abnormality (software). TH1 does not get to 50°C when a specified period of time has elapsed after the main power switch (SW1) turns ON for the fusing ON control.
Causes: Fusing temperature sensor /3 (TH3) Fusing heater lamp /3 (L3) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the fusing heating roller /Up (L3), and repair it if any abnormality. 10-N 2 Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. - 4 Check TH3 installed condition or the distance between TH3 and the fusing roller /Up, and adjust/replace it if any abnormality. 13-F 5 Replace TH3. - 6 Replace L3. - 7 Replace PRCB. - 8 Replace ACDB. - * After replacing the defective parts, be sure to set the DIPSW 3-1 to 0. DIPSW3-1 is set to 0 before defective parts are fixed, it causes fire.

← Xem tất cả mã lỗi Konica-Minolta bizhub Pro 1051

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie