Code: C-4306
Description: LPH fan (FM3) power abnormality. The FM3EM error detection signal is detected twice in succession within a specified period of time after FM3 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: LPH fan /1 (FM3) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 3 Replace FM3 and ACDB at a time.