Code: C-5010
Description: Communication error between the overall control board (OACB) and the printer control board (PRCB). Any of the following error is detected during data reception between OACB and PRCB. • Data head error • Data check sum error • Undefined command reception error • Occurrence of communication GA error vector
Causes: Printer control board (PRCB) Overall control board (OACB)
Remedy: 1 After turning OFF the sub power switch, turn OFF the main power switch and unplug the power plug. Restart the main body after 10 seconds. - 2 Check the connector connection and the wiring on OACB, and repair it if any abnormality. - 3 Check the connector connection and the wiring on PRCB, and repair it if any abnormality. - 4 Check the connector connection and the wiring between OACB and PRCB, and repair it if any abnormality. - 5 Replace OACB. - 6 Replace PRCB.