Code: C-5103
Description: Toner counter (CNT1) power abnormality 2. When CNT1 is turned ON from OFF, an error detection signal (blowout of ICP) is detected. At this time, an error detection signal (24V cut off) is not detected.
Causes: Total counter (CNT1) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and CNT1, and repair it if any abnormality. - 2 Check the CNT1, and repair/replace it if any abnormality. 10-K 3 Replace CNT1 and ACDB at a time.