Code: C-5328
Description: Suction cooling fan /1 (FM6) rotation abnormality 2. When the print is started, the EM signal of FM6 turns ON.
Causes: Suction cooling fan /1 (FM6) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 6-L 4 Replace FM6. - 5 Replace PRCB. - 6 Replace ACDB.