Code: C-5332
Description: Suction cooling fan /2 (FM7) rotation abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Suction cooling fan /2 (FM7) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM7. - 5 Replace PRCB. - 6 Replace ACDB.