Code: C-5351
Description: DC power supply /3 cooling fan (FM36) rotation abnormality 1. The FM36EM error detection signal is detected twice in succession within a specified period of time after FM36 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: DC power supply /3 cooling fan (FM36) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-L 3 Replace FM36. - 4 Replace PRCB.