Code: C-0222
Description: 1st tandem PF-702/703 upper tray up abnormality. PF-702: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20seconds after the paper lift motor /1 (M42) turns ON for lifting operation. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and /Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting.
Causes: Upper limit sensor /1 (PS2: PF-702) Upper limit sensor /1 (PS5: PF-703) Paper lift motor /1 (M42: PF-702) Paper lift motor /1 (M7: PF-703) PF drive board (PFUDB: PF-702/703)
Remedy: 1 Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality. - 2 Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-702: 5-C PF-703: 6-F 4 Check I/O and the operation of the sensor, and repair it if any abnormality. PF-702: 3-C PF-703: 3-F 5 Replace PS2: PF-702 or PS5: PF-703. - 6 Replace M42: PF -702 or M7: PF-703. - 7 Replace PFUDB.