Code: C-0282
Description: PI-PFU (PF-703)shutter motor /1 (M10) operation time abnormality 2. The M10EM error detection signal is detected twice in succession within a specified period of time after M10 was turned ON. At this time, an error detection signal (blowout of fan ICP) is detected.
Causes: Shutter motor /1 (M10: PF-703) PF drive board (PFUDB: PF-703)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PF-703: 15-L 3 Replace M10 and PFUDB at a time.