Code: C-0305
Description: Paper exit cooling fan /Up (FM4) power abnormality. The FM4EM error detection signal is detected twice in succession within a specified period of time after FM4 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Paper exit cooling fan /Up (FM4) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 3 Replace FM4 and ACDB at a time.