Code: C-0327
Description: Paper feed assist fan /Fr2 (FM23) power abnormality. The FM23EM error detection signal is detected twice in succession within a specified period of time after FM23 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Fr1 (FM21) Paper feed assist fan /Rr1 (FM20) Paper feed assist fan /Fr2 (FM23) Paper feed assist fan /Rr2 (FM24) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-F, 8-F 3 C-0321: Replace FM21 and PRCB at a time. C-0324: Replace FM20 and PRCB at a time. C-0327: Replace FM23 and PRCB at a time. C-0330: Replace FM24 and PRCB at a time.