Code: C-0391
Description: PI-PFU (PF-703) paper feed assist fan /Rr2 (FM6) power abnormality. The FM6EM error detection signal is detected twice in succession within a specified period of time after FM6 was turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Rr2 (FM4: PF-702) Paper feed assist fan /Rr2 (FM6: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 11-F 3 Replace FM4 and PFUDB at a time: PF-702 Replace FM6 and PFUDB at a time: PF-703