Mã lỗi C-1102 — Konica-Minolta bizhub Pro 1200

Code: C-1102

Description: Tray up down drive abnormality. The tray up down motor (M3) does not turn OFF even when a specified period of time elapses after it starts operations. Or, it operates for more than the allowed time at a speed out of the specified one.
Causes: Tray lower limit sensor (PS3: FS-521) Tray upper limit sensor (PS16: FS-521) Tray upper limit LED (LED1: FS-521) Tray up down motor (M3: FS-521) FNS drive board (FNSDB: FS-521) FNS control board (FNSCB: FS-521)
Remedy: 1 Check the tray up/down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FNSDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between FNSDB and FNSCB, and repair it if any abnormality. - 4 Check the sensor operation, LED emission and light-receiving path, and repair/ replace it if any abnormality. FS-521: 2-B, 4-B 5 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FS-521: 1-B 6 Replace PS3. - 7 Replace LED1 and PS16. - 8 Replace M3. - 9 Replace FNSDB. - 10 Replace FNSCB.