Code: C-1212
Description: 2nd tandem LS-505 shift unit motor (M5) drive abnormality. The shift unit home sensor (PS11) does not turn OFF within a specified period of time after M5 turns ON. Or, PS11 does not turn ON within a specified period of time. 33-7
Causes: Shift unit home sensor (PS11: LS-505) Shift unit motor (M5: LS-505) LS control board (LSCB: LS-505)
Remedy: 1 Check the shift unit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS11. - 6 Replace M5. - 7 Replace LSCB.