Code: C-1224
Description: 2-hole operation abnormality. The 2-holes punch home sensor (PS8) does not turn OFF within a specified period of time after the 2-holes punch home position return operation starts. Or, after the punch motor (M10) turns ON, the 2- holes punch home sensor (PS8) does not turn OFF. 33-0
Causes: 2 holes punch home sensor (PS8: FD-503) Punch motor (M10: FD-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the 2-hole punch section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 5-F 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 5-E 5 Replace PS8. - 6 Replace M10. - 7 Replace PDB.