Code: C-1228
Description: Exit tray operation abnormality 1. The main tray upper limit sensor (PS20) does not turn ON within a specified period of time after the main tray home position search starts. Or, after the tray up down motor (M11) turns ON, the main tray upper limit sensor (PS20) does not turn OFF. 33-2
Causes: Main tray upper limit sensor (PS20: FD-503) Tray up down motor (M11: FS-503) Punch drive board (PDB: FD-503)
Remedy: 1 Check the punch alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 3-D 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 6-D 5 Replace PS20. - 6 Replace M11. - 7 Replace PDB.