Mã lỗi C-1245 — Konica-Minolta bizhub Pro 1200

Code: C-1245

Description: Bundle arm motor (M10) drive abnormality. The bundle arm home sensor (PS32) does not turn ON even after a specified period of time after M10 starts the home position search operation. Or, even after a specified period of time after M10 starts the operation, it does not stop. Bundle arm motor (M10) 34-0/1/3
Causes: Bundle arm home sensor (PS32: SD-506) Bundle arm motor (M10: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the bundle arm section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 19-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 17-D 6 Replace PS32. - 7 Replace M10. - 8 Replace SDDB. - 9 Replace SDCB.