Code: C-1260
Description: Guide shaft motor (M25) drive abnormality. The guide shaft home sensor (PS46) does not turn ON even after a specified period of time after M25 starts the home position search operation. Or, even after a specified period of time after M25 starts the operation, it does not stop. 34-0/1/3
Causes: Guide shaft home sensor (PS46: SD-506) Guide shaft motor (M25: SD-506) SD drive board (SDDB: SD-506) SD control board (SDCB: SD-506)
Remedy: 1 Check the guide shaft, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between SDDB and motor/sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDDB and SDCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. SD-506: 11-D 5 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. SD-506: 15-D 6 Replace PS46. - 7 Replace M25. - 8 Replace SDDB. - 9 Replace SDCB.