Code: C-1281
Description: FD alignment motor (M3) drive abnormality. The FD alignment home sensor (PS3) does not turn ON even after a specified period of time after M3 starts the home position search operation. Or, even after a specified period of time after M3 starts the operation, it does not stop.
Causes: FD alignment home sensor (PS3: RU-506) FD alignment motor (M3: RU-506) RU control board (RUCB: RU-506)
Remedy: 1 Check the FD alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. RU-506: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. RU-506: 5-B 5 Replace PS3. - 6 Replace M3. - 7 Replace RUCB