Code: C-1517
Description: PB-502: Abnormality of the glue supply. The count of a specified number of pellets, which is counted by the pellet count sensor (PS37), has not been reached after the pellet supply motor (M33) turns ON. The status was detected by a specified number of times in succession. PB-503: Abnormality of the glue supply. The supply operation which the pellet supply passage sensor (PS37) does not turn ON is detected twice in succession after turning ON the pellet supply pipe motor (M33). 35-4
Causes: Pellet supply motor (M33: PB-502) PB drive board (PBDB: PB-502) PB drive board /1 (PBDB1: PB-503) PB control board (PBCB: PB-502, PB-503)
Remedy: 1 Check the pellet supply section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PBDB/PBDB1 and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between PBDB/PBDB1 and PBCB, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. PB-502: 10-D PB-503: 10-D 5 Replace M33. - 6 Replace PBDB (PB-502), PBDB1 (PB-503). - 7 Replace PBCB.