Mã lỗi C-2101 — Konica-Minolta bizhub Pro 1200

Code: C-2101

Description: Charger cleaning motor (M23) operation time abnormality. • When the charger cleaning home sensor (PS26) is OFF with the main power switch (SW1) ON, PS26 does not turn ON within 35seconds after the M23 turns ON for home position research operation (return operation). At this time, an error detection signal (blowout of ICP) is not detected. • PS26 does not turn OFF within 15seconds after the reverse operation (return operation) is started. At this time, an error detection signal (blowout of ICP) is not detected. • The charge cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, PS26 does not turn ON within a specified period of time after PS27 turns ON. At this time, an error detection signal (blowout of ICP) is not detected. • When PS26 and PS27 are ON at the start of cleaning operation
Causes: Charger cleaning home sensor (PS26) Charger cleaning limit sensor (PS27) Charger cleaning motor (M23) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 16-F 4 Replace PS26 or PS27. - 5 Replace M23. - 6 Replace PRCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub Pro 1200

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie