Code: C-2228
Description: The transfer belt motor (M30) rotation abnormality. The M30EM error detection signal is detected twice in succession within a specified period of time after M30 was turned ON. However, an error detection signal (blowout of ICP) is not detected.
Causes: Transfer belt motor (M30) ADU drive board (ADUDB) Printer control board (PRCB)
Remedy: 1 Check the transfer belt, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-O 5 Replace M30. - 6 Replace PRCB. - 7 Replace ADUDB.