Mã lỗi C-2235 — Konica-Minolta bizhub Pro 1200

Code: C-2235

Description: Transfer belt pressure release motor (M26) operation time abnormality 2. • The transfer pressure home sensor (PS54) ON is not detected within a specified period of time after the main power turns ON. At this time, the main door detection is Close. • When M26 moves from the pressure position to the HP position, PS54 does not turn ON within a specified period of time. At this time, the main door detection is Close.
Causes: Transfer pressure home sensor (PS54) Transfer belt pressure release motor (M26) ADU drive board (ADUDB)
Remedy: 1 Check the transfer belt pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between ADUDB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 19-L 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 21-L 5 Replace PS54. - 6 Replace M26. - 7 Replace PRCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub Pro 1200