Code: C-2303
Description: Developing suction fan /1 (FM9) rotation abnormality. The FM9EM error detection signal is detected twice in succession within a specified period of time after FM9 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Developing suction fan /1 (FM9) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 5-L 3 Replace FM9. - 4 Replace PRCB.