Code: C-3103
Description: Fusing pressure release motor (M33) operation time abnormality 2. The fusing pressure home sensor (PS58) ON is not detected within a specified period of time after the main power turns ON. When M33 moves from the pressure position to the release position, PS58 does not turn ON within a specified period of time.
Causes: Fusing pressure home sensor (PS58) Fusing pressure release motor (M33) Printer control board (PRCB)
Remedy: 1 Check the fusing pressure release section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. - 3 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. 13-F 4 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 5 Replace PS58. - 6 Replace M33. - 7 Replace PRCB.