Mã lỗi C-4303 — Konica-Minolta bizhub Pro 1200

Code: C-4303

Description: Image processing cooling fan (FM12) rotation abnormality 1. The FM12EM error detection signal is detected twice in succession within a specified period of time after FM12 was turned ON. However, error detection signals (24V cut off/blowout of ICP) are not detected.
Causes: Image processing cooling fan (FM12) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 4 Replace FM12. - 5 Replace PRCB. - 6 Replace ACDB.