Code: C-5318
Description: Cooling fan /1 (FM1) power abnormality. The FM1EM error detection signal is detected twice in succession within a specified period of time after FM1 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Cooling fan /1 (FM1) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 4-L 3 Replace FM1 and ACDB at a time.