Code: C-5331
Description: Suction cooling fan /2 (FM7) power abnormality. The EM error detection signal of FM7 is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of ICP) is detected.
Causes: Suction cooling fan /2 (FM7) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 7-L 3 Replace FM7 and ACDB at a time