Code: C-6303
Description: Scanner cooling fan (FM19) rotation abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, an error detection signal (blowout of a fuse/24V cut off) is not detected.
Causes: Scanner cooling fan (FM19) Scanner drive board (SDB) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. - 2 Check the connector connection and the wiring between SDB and PRCB, and repair it if any abnormality. - 3 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. 2-F 4 Replace FM19. - 5 Replace SDB. - 6 Replace PRCB.