Code: C-6721
Description: AGC retry. The AGC is retried due to the decreased light volume of the exposure lamp. However, no error occurs.
Causes: Exposure lamp (L4) L4 inverter (L4_INVB) Scanner drive board (SDB) CCD board (CCDB)
Remedy: 1 Check the reading section, and repair it if any abnormality such as cover off. - 2 Check the connector connection and the wiring between IPB and CCDB, and repair it if any abnormality. - 3 Check the connector connection and the wiring between SDB and L4_INVB/ between L4_INVB and L4, and repair it if any abnormality. 2-F 4 When L4 is high-light intensity, low-light intensity or does not light, replace L4. - 5 When L4 is high-light intensity, low-light intensity or does not light after replacing L4, replace L4_INVB. - 6 Replace CCDB. -