Code: C-C115
Description: ISW write abnormality on RU. The firmware is not written on RU, or an error is detected during the ROM check.
Causes: IC board (ICB) PCI relay board (PCIRB) Overall control board (OACB)
Remedy: 1 Check to see that the jumper connector is properly set in the manner that is explained in FIRMWARE VERSION UP in the MAINTENANCE, and reinstall it if any abnormality. - 2 Check the connector connection and the wiring between the main body and each option, and repair it if any abnormality. - 3 Check the I/F connector connection and the wiring for ISW on ICB, and repair it if any abnormality. 21-C 4 Check the connector connection and the wiring between ICB and OACB, and repair it if any abnormality. - 5 Reinstall the firmware of the option corresponds to the malfunction code. - 6 Replace OACB.