Mã lỗi C-0312 — Konica-Minolta bizhub Pro 1200P

Code: C-0312

Description: Paper exit cooling fan /Lw2 (FM28) rotation abnormality. The FM28EM error detection signal is detected twice in succession within a specified period of time after FM28 was turned ON. However, error detection signals (24V cut off/ICP blowout) are not detected.
Causes: Paper exit cooling fan /Lw2 (FM28) Printer control board (PRCB) AC drive board (ACDB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the fun, and repair it if any abnormality. - 2 Check the connector connection and the wiring between ACDB and the fun, and repair it if any abnormality. - 3 Rotate the fun or I/O by hand, and repair it if any abnormality. 4-L 4 Replace FM28. - 5 Replace PRCB. - 6 Replace ACDB.