Mã lỗi C-0347 — Konica-Minolta bizhub Pro 1200P

Code: C-0347

Description: 1st tandem PF-702/703 paper feed assist fan /Fr2 (FM3: PF-702, FM5: PF-703) power abnormality. The FM3EM and FM5EM error detection signals are detected twice in succession within a specified period of time after FM3 and FM5 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Fr2 (FM3: PF-702) Paper feed assist fan /Fr2 (FM5: PF-703) PF drive board (PFUDB)
Remedy: 1 Check the connector connection and the wiring between PFUDB and the fun, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. PF-702: 7-C PF-703: 10-F 3 Replace FM3 and PFUDB at a time: PF-702 Replace FM5 and PFUDB at a time: PF-703