Code: C-0353
Description: 1st tandem PF-702/703 paper feed assist fan /Fr3 (FM5: PF-702, FM9: PF-703) power abnormality. The FM5EM and FM9EM error detection signals are detected twice in succession within a specified period of time after FM5 and FM9 were turned ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Paper feed assist fan /Fr3 (FM5: PF-702) Paper feed assist fan /Fr3 (FM9: PF-703) PF drive board (PFUDB)