Mã lỗi C-1282 — Konica-Minolta bizhub Pro 1200P

Code: C-1282

Description: CD alignment motor (M4) drive abnormality. The CD alignment home sensor (PS4) does not turn ON even after a specified period of time after M4 starts the home position search operation. Or, even after a specified period of time after M4 starts the operation, it does not stop.
Causes: CD alignment home sensor (PS4: RU-506) CD alignment motor (M4: RU-506) RU control board (RUCB: RU-506)
Remedy: 1 Check the CD alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between RUCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. RU-506: 2-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. RU-506: 5-B 5 Replace PS4. - 6 Replace M4. - 7 Replace RUCB