Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-2102 — Konica-Minolta bizhub Pro 1200P

Code: C-2102

Description: Charger cleaning motor (M23) power abnormality. • When the charger cleaning home sensor (PS26) is OFF with the main power switch (SW1) ON, PS26 does not turn ON within 35seconds after the M23 turns ON for home position research operation (return operation). And at this time, an error detection signal (blowout of ICP) is detected. • PS26 does not turn OFF within 15seconds after the reverse operation (return operation) is started. And at this time, an error detection signal (blowout of ICP) is detected. • The charge cleaning limit sensor (PS27) does not turn ON within a specified period of time after the reverse operation (return operation) is started for detection of PS26 being OFF. Or, PS26 does not turn ON within a specified period of time after PS26 turns ON. At this time, an error detection signal (blowout of ICP) is detected.
Causes: Charger cleaning motor (M23) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 16-F 3 Replace M23 and PRCB.

← Xem tất cả mã lỗi Konica-Minolta bizhub Pro 1200P

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie