Mã lỗi C-2208 — Konica-Minolta bizhub Pro 1200P

Code: C-2208

Description: Blade motor (M22) power abnormality. The blade READY signal (READY condition) cannot be detected within a specified period of time after the blade replacement signal turns ON. Or, the blade READY signal (READY release condition) cannot be detected within a specified period of time after the blade replacement signal turns OFF. At this time, an error detection signal (blowout of ICP) of the blade motor (M22) is detected.
Causes: Blade motor (M22) Printer control board (PRCB)
Remedy: 1 Check the connector connection and the wiring between PRCB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. 15-F 3 Replace M22 and PRCB at a time.