Mã lỗi C-5329 — Konica-Minolta bizhub Pro 1200P

Code: C-5329

Description: Abnormality of the fun connected to ADU drive board. The EM error detection signal is detected twice in succession within a specified period of time after ADU cooling fan /1 (FM14), /2 (FM15), /3 (FM13), sensor cooling fan /1 (FM16) and registration cooling fan (FM17) connected to ADU drive board was turned ON. At this time, the door close detection of the door open/close sensor /1 (PS1), /2 (PS2) and PF door open/close sensor (PS70) is detected 10 times in succession.
Causes: ADU cooling fan /1 (FM14) ADU cooling fan /2 (FM15) ADU cooling fan /3 (FM13) Sensor cooling fan (FM16) Registration cooling fan (FM17) ADU drive board (ADUDB)
Remedy: 1 Check the connector connection and the wiring between ADUDB and the fan, and repair it if any abnormality. - 2 Rotate the fan by I/O or hand, and repair/replace it if any abnormality. - 3 Replace the fan. - 4 Replace ADUDB.