Code: C-6719
Description: The original skew adjustment is too late. The scan operation starts before the original skew adjustment is terminated.
Causes: Original skew sensor /Fr (PS312: DF-615) Original skew sensor /Rr (PS311: DF-615) DF control board (DFCB: DF-615) Overall control board (OACB: main body)
Remedy: 1 Check the original skew sensor, and repair it if any abnormality. DF-615: 2-G 2 Check the connector connection and the wiring between DFCB and the sensor, and repair it if any abnormality. - 3 Check the connector connection and the wiring between IDFCB and OACB, and repair it if any abnormality. - 4 Conduct the DF paper skew adjustment of the mechanical adjustment to correct the original skew. - 5 Conduct [Service mode]-[Process adjustment]-[ADF Skew Offset Adj.] - 6 Replace PS311 or PS312. - 7 Replace DFCB - 8 Replace OACB.