Mã lỗi C-0240 — Konica-Minolta bizhub Pro 951

Code: C-0240

Description: 2nd tandem PF-703/706 upper tray up abnormality. PF-703: When the upper limit sensor /1 (PS5) is OFF, PS5 does not turn ON within 20 seconds after the paper lift motor /1 (M7) turns ON for lifting operation. Or, the paper suction sensor /Fr1 and / Rr1 (PS25 and PS26) turn ON before PS5 turns ON while in tray lifting. PF-706: When the upper limit sensor /1 (PS2) is OFF, PS2 does not turn ON within 20 seconds after the paper lift motor /1 (M42) turns ON for the lifting operation.
Causes: • Upper limit sensor /1 (PS5: PF-703) • Upper limit sensor /1 (PS2: PF-706) • Paper lift motor /1 (M7: PF-703) • Paper lift motor /1 (M42: PF-706) • PF drive board (PFUDB: PF-703/706) DIPSW20-5
Remedy: 1. Check the paper loaded condition and the rear end restriction plate misaligned of the upper tray, and repair it if any abnormality 2. Check the connector connection and the wiring between PFUDB and motor/sensor, and repair it if any abnormality 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality (Wiring diagram: PF-703: 6-F, PF-706: 5-C) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: PF-703: 3-F, PF-706: 3-C) 5. Replace PS5: PF-703 or PS2: PF-706 6. Replace M7: PF -703 or M42: PF-706 7. Replace PFUDB.

← Xem tất cả mã lỗi Konica-Minolta bizhub Pro 951

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie