Mã lỗi C-1226 — Konica-Minolta bizhub Pro 951

Code: C-1226

Description: The alignment plate home sensor (PS10) does not turn ON within a specified period of time after the alignment plate home position return operation starts. Or, after the alignment motor (M12) turns ON, the alignment plate home sensor (PS10) does not turn OFF.
Causes: • Alignment motor (M12) • Punch drive board (PDB) • Alignment plate home sensor (PS10) DIPSW6-0
Remedy: 1. Check the punch alignment section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. 3. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram:FD-503:3-D) 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram:FD-503:5-D) 5. Replace PS10. 6. Replace M12. 7. Replace PDB.