Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi C-1566 — Konica-Minolta bizhub Pro 951

Code: C-1566

Description: Relay conveyance exit motor drive abnormality A rotation error detection signal is detected for a specified period of time in succession while the relay conveyance exit motor (M91) is driving.
Causes: • Relay conveyance exit motor (M91) • PB control board (PBCB) • PB drive board (PBDB)
Remedy: 1. Check the relay conveyance paper exit section, and clean/repair it if any abnormality. 2. Check the connector connection and the wiring between PBDB1 and the motor, and repair it if any abnormality. 3. Check the connector connection and the wiring between PBDB2 and the motor, and repair it if any abnormality. 4. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: PB-503: 26-W) 5. Replace M91. 6. Replace PBDB2. 7. Replace PBDB1. 8. Replace PBCB.