Mã lỗi C-3102 — Konica-Minolta bizhub Pro 951

Code: C-3102

Description: Fusing pressure release motor (M33) operation time abnormality 1. When M33 moves from the release position to the pressure position, the fusing pressure home sensor (PS58) does not turn ON within a specified period of time.(PRO 951 is unimplemented) The same abnormality occurs when the fusing unit exclusively for PRO 951 is set to PRESS 1250/1250P/1052.
Causes: • Fusing unit • Fusing pressure position sensor (PS58) • Fusing pressure release motor (M33) • Printer control board (PRCB)
Remedy: 1. Check that the proper fusing unit is installed, and replace it if the wrong one is installed 2. Check the fusing pressure release section, and clean/repair it if any abnormality. 3. Check the connector connection and the wiring between PRCB and motor/sensor, and repair it if any abnormality. 4. Check I/O and the operation of the sensor, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4): 7-I). 5. Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. (Wiring diagram: Main body (3/4):7-I) 6. Replace PS58. 7. Replace M33. 8. Replace PRCB.