Mã lỗi C-3504 — Konica-Minolta bizhub Pro 951

Code: C-3504

Description: Thermistor /3 (TH3) high temperature abnormality (hardware). TH3 detects the fusing abnormality detection 4.
Causes: • Fusing temperature sensor /3 (TH3) • Fusing heater lamp /3 (L3) • Printer control board (PRCB) • AC drive board (ACDB)
Remedy: 1. Check the fusing heater lamp /3 (L3), and repair it if any abnormality. (Wiring diagram: Main body (1/4): 4-A) 2. Check the connector connection and the wiring between PRCB and TH1, and repair it if any abnormality. 3. Check the connector connection and the wiring between ACDB and L3, and repair it if any abnormality. 4. Check TH3 to see the installed position or distance to the fusing roller /Up, and adjust/replace it if any abnormality. (Wiring diagram: Main body (1/4): 23-B) 5. Replace TH3. 6. Replace L3. 7. Replace PRCB. 8. Replace ACDB.