Code: C-5332
Description: Suction cooling fan /2 (FM6) rotation abnormality. The FM7EM error detection signal is detected twice in succession within a specified period of time after FM7 was turned ON. At this time, an error detection signal (24V cut off) is not detected.
Causes: • Suction cooling fan /2 (FM7) • Printer control board (PRCB) • AC drive board (ACDB)
Remedy: 1. Check the connector connection and the wiring between PRCB and the fan, and repair it if any abnormality. 2. Check the connector connection and the wiring between ACDB and the fan, and repair it if any abnormality. 3. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (2/4): 7-A) 4. Replace FM7. 5. Replace PRCB. 6. Replace ACDB.