Code: C-6302
Description: Scanner cooling fan (FM19) power abnormality. The FM19EM error detection signal is detected twice in succession within a specified period of time after FM19 was turned ON. At this time, 24V is normal, but an error detection signal (blowout of a fuse) is detected.
Causes: • Scanner cooling fan (FM19) • Scanner drive board (SDB)
Remedy: 1. Check the connector connection and the wiring between SDB and the fan, and repair it if any abnormality. 2. Rotate the fan or I/O by hand, and repair it if any abnormality. (Wiring diagram: Main body (4/4): 15-K) 3. Replace FM19 and SDB.