Code: C0045
Description: Fusing Section Cooling Fan Motor’s failure to turn
A voltage of 0.3 V or less is detected for a continuous 1 s period while the motor remains energized.
A voltage of 0.3 V or less is detected for a continuous 1 s period while the motor remains energized.
Remedy: 1 Fusing Section Cooling Fan Motor operation: the voltage across CN7-2 on the Power Supply Board and GND is DC24 V after the malfunction has been reset. NO Change Power Supply Board. 2 Fusing Section Cooling Fan Motor operation: the voltage across CN7-1 on the Power Supply Board and GND is DC1.2 V (during high-speed rotation) and DC12 V (during low-speed rotation) after the malfunction has been reset. YES Change motor. NO Change Power Supply Board. Change Master Board.