Code: C0049
Description: PH Section Cooling Fan Motor’s failure to turn
A voltage of 0.35 V or less is detected for a continuous 0.5 s period while the motor remains energized.
A voltage of 0.35 V or less is detected for a continuous 0.5 s period while the motor remains energized.
Remedy: 1 PH Section Cooling Fan Motor operation: the voltage across PJ13A-2 on the Master Board and GND is DC24 V after the malfunction has been reset. NO Change Master Board. 2 PH Section Cooling Fan Motor operation: the voltage across PJ13A-1 on the Master Board and GND is DC1 V (motor energized) and DC24 V (motor deenergized) after the malfunction has been reset. YES Change motor. NO Change Master Board.