Mã lỗi C0510 — Konica-Minolta Di151

Code: C0510

Description: Abnormally low fusing temperature
• The temperature detected by the Thermistor remains lower than 94 °C for a continuous 50 ms period while the copier is in the standby state. • The temperature detected by the Thermistor remains lower than 110 °C for a continuous 50 ms period during a copy cycle.
Remedy: 1 Fusing Heater Lamp turns ON after the malfunction has been reset. YES Correct Thermistor for mounting position and/or clean. 2 Thermistor operation: resistance across CN1-1 and 2 on the Fusing Unit side is infinite, as measured with CN1 disconnected. YES Change Thermistor. 3 Thermoswitch and Fusing Heater Lamp operation: there is continuity across CN14-1 and 2 on the Fusing Unit side, as measured with CN14 disconnected. NO Change Thermoswitch. Change Fusing Heater Lamp. 4 The voltage across PJ14A-3 on the Master Board and GND is DC0 V (Fusing Heater Lamp ON) and DC24 V (Fusing Heater Lamp OFF) after the malfunction has been reset. YES Change Power Supply Board. Change Fuse 2 of Power Supply Board. NO Change Master Board.